Why does the fan keep running on my furnace?

Why does the fan keep running on my furnace?

You’re using the wrong thermostat fan setting. Your fan limit switch is on “manual override” There’s a shorted thermostat wire. There’s a shorted wire at the fan limit switch.

What does a indoor fan relay do?

The fan delay relay is a tuned relay that keeps the indoor blower motor running to take advantage of this continued refrigeration and of the coil that is still cold after the refrigeration cycle has stopped. Most relays operate flow for about 60 seconds and then shut off.

What are the symptoms of a bad fan relay?

Bad Cooling Fan Relay Symptoms

  • The engine runs hot or overheats.
  • The cooling fans don’t work.
  • The cooling fans keep running.
  • Warning lights.
  • Poor air conditioning performance.
  • Swapping Relays.
  • Measuring the Relay Coil’s Resistance.
  • Listening for Noises.

Why does my furnace blower fan keep running?

Well, if your furnace blower fan won’t stop running, you could have any of the following problems: 1 You’re using the wrong thermostat fan setting 2 Your fan limit switch is on “manual override” 3 There’s a shorted thermostat wire 4 There’s a shorted wire at the fan limit switch

Where is the fan limit switch on my furnace?

If your furnace fan is set to AUTO and is still running, then move on to the next section. Your fan limit switch is located directly under your furnace hood and controls when your furnace blower turns on and off.

What to do if your Riello burner wont start?

If it is spinning OK when you tap it, try running the motor with the fan cover off and see how easy it is to stop the fan (with a piece of wood) and whether it restarts OK. Try starting the motor by spinning the fan when it is stuck.

Why is my fan limit switch not pressed in?

If your fan limit switch was already set to AUTO (not pressed in), then you most likely either have a problem with your thermostat wiring or the fan limit switch is bad.

Well, if your furnace blower fan won’t stop running, you could have any of the following problems: 1 You’re using the wrong thermostat fan setting 2 Your fan limit switch is on “manual override” 3 There’s a shorted thermostat wire 4 There’s a shorted wire at the fan limit switch

What happens when a blower motor relay wears out?

Without it, the AC system will not be able to circulate any heated or cooled air. The blower motor relay controls the current used to power the blower motor, and is subject to the constant on and off switching. Over time, it can eventually wear out.

What to do if your a / C fan won’t stop running?

1. At the room thermostat: the FAN-AUTO-OFF or FAN ON/OFF switch on the room thermostat should be checked. The fan control should be set to AUTO. You can try turning the switch to OFF too. Other snafus such as a shorted thermostat wire can also cause the A/C or warm air furnace fan to run continuously.

If your furnace fan is set to AUTO and is still running, then move on to the next section. Your fan limit switch is located directly under your furnace hood and controls when your furnace blower turns on and off.

You Might Also Like